The IDC connectors were used to connect the drops to the buss wires. We had the proper Scotckloc connector for #12 wire and they worked well for 5 years.
We then began to notice that the trains would slow down on certain sections of track and were not sure why. An inspection of the wiring showed nothing wrong and in the process of checking the wiring the problems seemed to go away.
While this was OK it did not really explain why the problems even showed up. Then a different section of track began giving problems. We had the layout set up blocks using industrial toggle switches and it was designed to be able to have 2 different transformers available to run any given section of track. So the transformers were not the problem as either one would not make the track run any better.
It got so bad at the last we had to have the bad sections set on the other transformer set to a higher voltage just to keep the trains moving at the same speed section to section. Then on the forums someone stated that the potential problems existed where the metal blades came in contact with the wire and very minute amounts of corrosion would form on the IDCs.
This then explained why when we did our wiring inspections we seemed to correct the power loss but had not actually done anything except moving the wires around. By moving the wires we must have made good contact again by somehow breaking through the corrosion. I really could not see any of this in any of the connectors but then it probably was that very small amount.
We subsequently rebuilt the Lionel display at our club and we are NOT using the IDC connectors PERIOD ! We are soldering all connections.
BOB H – Clarion, PA